When is a nasal cannula enough, and when do you ventilate with a bag-valve mask?
A patient who is breathing with adequate tidal volume and only mild hypoxia can start on a nasal cannula, typically about 1–6 liters per minute. A nonrebreather mask at about 10–15 liters per minute is the high-flow device for a patient who is still breathing adequately but needs more oxygen; the reservoir should stay inflated. A bag-valve mask is for inadequate rate or depth, not for a patient who is ventilating well. An adult with a pulse and inadequate breathing is ventilated at about one breath every 6 seconds, with just enough volume to see the chest rise. Faster or deeper breaths reduce venous return. A standard pulse oximeter does not detect carbon monoxide, so a high reading does not clear a patient from a closed-space generator or a running engine. Scene safety comes before any oxygen. Continuous positive airway pressure, where a protocol allows it, needs a patient who is alert, protecting the airway, and able to tolerate the mask. Vomiting, hypotension, and respiratory arrest are common reasons not to use it.
CDC — About carbon monoxide · American Heart Association — CPR and ECC guidelines