Why must a citrate tube be full, and how are additive tubes mixed?

A sodium citrate tube is calibrated for a 9:1 ratio of blood to anticoagulant. An underfilled citrate tube is not a valid coagulation specimen, because the extra anticoagulant changes the result. When a winged set is used and citrate is the first tube, draw a discard tube first so air in the tubing does not underfill the citrate tube; the discard tube itself does not have to fill. After filling, invert additive tubes gently the number of times the manufacturer states. Do not shake. Inversion counts differ by additive and by manufacturer, so the package insert controls the count rather than a single number memorized for every tube.